OU1PU – Sets Output 1 as pulsed
OU1LA – Sets Output 1 as latched
OU1PT – Sets Output 1 pulse time in
milliseconds
OU2PU – Sets Output 2 as pulsed
OU2LA – Sets Output 2 as latched
OU2PT – Sets Output 2 pulse time in
milliseconds
OU3PU – Sets Output 3 as pulsed
OU3LA – Sets Output 3 as latched
Output
Settings
Settings Parameters
CT (Call Time) – Sets the maximum
duration of the call (the call can be
terminated earlier by either party)
RT (Ring Time)– Sets the time before
which the unit will disconnect if a call is
unanswered
HT (Hang Time) – Sets the time for
which the call remains connected after
a DTMF event
Sub-parameters:
Call time (seconds)
Ring time (seconds)
Hang time (seconds)
Description
Call
CO
Configure inputs,
outputs and system
settings
CO
Filter Time is defined as the minimum time that the signal must be asserted before it is
seen as valid. For example, if an input is configured to send a notification upon a falling
edge signal being asserted – say, when mains power to an irrigation system fails – and
the Filter Time has been set to ten seconds, the notification will only be sent if the falling
edge signal has been present for at least ten seconds.
Blanking Time, on the other hand, refers to the minimum or ‘cool down’ period before
an asserted input will respond to any subsequent assertions. For example, an input’s
Blanking Time has been set to one hour and the input gets asserted and sends an SMS
notification. One minute later, the input is asserted again. This second assertion will be
ignored until an hour has passed.
Filter and Blanking Time(G-SPEAK CLASSIC+ only)
More than one configuration setting can be applied/edited using a single SMS by
separating the commands with a full stop. In the case of the G-SPEAK Classic+ all I/Os
(configurable inputs and outputs) are defaulted as outputs and may be reconfigured to be
inputs, whereas the G-SPEAK Classic only has one output which cannot be configured
to be an input. Where channels have been set up to act as inputs only (G-SPEAK
CLASSIC+ only), further parameters can be set by specifying Filter and Blanking Times.