page 12
3. Lift the Calling Module off base.
4. Hold the Calling Module base against the
wall at the required height, ensuring that
it is vertical.
5. Mark the location of the mounting holes.
6. Using a 5mm masonry bit, drill holes into
the wall for the rawlplugs provided in the
kit.
7. If the cable is being routed into the unit
from a concealed conduit behind the
base, knock out one of the cable entry
holes provided in the base and feed
through the cable. Ensure that at least
100mm of cable extends out of the wall.
8. Fit sealing washer onto the mounting
screw before installing as shown in
Figure 11.
9. Screw the base firmly into position and
using the slots provided in the mounting
holes, adjust the base to be perfectly
vertical.
10. Ensure that sealing washer is fitted and
closes off the mounting hole to prevent
water ingress as shown in Figure 12.
FIGURE 10.
Calling
Module
Calling
Module
base
FIGURE 11.
Calling
Module
Rawlplug
Cable
Mounting hole
Mounting
screw
FIGURE 12.
Sealing washer
Mounting
screw
Sealing
washer